Status Indicators and Alarm Relay

4-1

Chapter 4
Testing and Diagnostics

This chapter describes the FOM-E1/T1 diagnostics functions, which include:
• Front panel LED indicators
• Alarm relay
• Diagnostic loopbacks.

In addition, this chapter provides some tips on troubleshooting and frequently
asked questions.

4.1 Status Indicators and Alarm Relay

Front Panel LEDs

The status of FOM-E1/T1 is indicated by the front panel LED indicators. For

description of LED indicators and their functions, refer to

Chapter 3

.

Alarm Relay

FOM-E1/T1 supports dry contact alarm relay via reserved pins of the DB-15 female
connector. The following fault conditions trigger relay of the major and minor
alarms:
• Major alarms are initiated when E1/T1 electrical input becomes lower than

G.703 electrical levels, or bit error rate at the fiber optic interface is 10

-6

or

worse.

• Minor alarms occur when an Alarm Indication Signal is received at the E1/T1

electrical or fiber optic interfaces.

Table 4-1

lists the DB-15 connector pins used for the alarm relay.

Table 4-1. DB-15 Connector, Alarm Relay Pins

Pin Contact

Alarm

Type

7, 8

Normally Closed

15, 8

Normally Open

Minor

5, 6

Normally Closed

13, 6

Normally Open

Major