Chapter 2 Installation and Setup

FOM-E1/T1 Installation and Operation Manual

2-4

Installation and Setup

Table 2-1 FOM-E1/T1 Internal Jumpers and Switches

Jumper/Switch Function

Possible

Settings

Factory
Setting

SW3, AIS

When a major alarm is

detected, AIS is

transmitted to either the
electrical or optical

interface.

ON – Transmit AIS
OFF – Do not transmit AIS

ON

SW2, INPUT Ground
SW1, OUTPUT Ground

Controls connection of
the BNC shield to the

chassis ground

CONNECTED – BNC shield is

connected to the

chassis ground

(for E1 unbalanced)

FLOATING – BNC shield is

disconnected from the

chassis ground

(for E1/T1 balanced)


FLOATING

JP2, JP4, JP5, JP6, JP7, JP8,

INTERFACE

Selects the E1/T1

electrical interface

100 ohm BAL T1 – T1 100Ω balanced

(DB-15 connector)

120 ohm BAL CEPT – E1 120Ω

balanced

(DB-15
connector)

75 ohm UNBAL CEPT – E1 75Ω

unbalanced

(BNC
connectors)



120 ohm

BAL CEPT

Note:

For

FOM-E1/T1

units with 115 VAC, factory setting is 100 BAL T1.

Connecting the Interfaces

Figure 2-2

illustrates the AC-powered FOM-E1/T1 unit rear panel.

IN

TX

OUT

RX

Figure 2-2 FOM-E1/T1 Rear Panel, AC-Powered Unit

Connecting the Fiber Optic Interface

Two fiber optic ST, SC or FC connectors are located on the rear panel and marked
TX and RX.

To connect the fiber optic cables
1. Remove the protective caps from the connectors and store them in a safe

place for later use.