Technical specifications, 4 technical specifications – RAD Data comm T1 User Manual

Page 19

Advertising
background image

FOM-E1/T1 Installation and Operation Manual

Chapter 1 Introduction

Technical Specifications

1-5

1.4 Technical Specifications

E1/T1
Interface

Transmission Rates

E1: 2.048 Mbps
T1: 1.544 Mbps

Interface

User-selectable:
• E1: 120Ω balanced or 75Ω unbalanced
• T1: 100Ω balanced

Zero Suppression

E1: HDB3
T1: B8ZS

Connectors

Balanced: 15-pin D-type, female
Unbalanced: two BNC

Optical
Interface

Operating
Wavelength

See

Table 1-1

Receiver Sensitivity

For BER 10

-9

:

• -38 dBm at 850 nm
• -40 dBm at 1310 nm or 1550 nm

Connectors

ST, SC or FC

Dynamic Range

28 dB for all types of optical interfaces

Budget (Max)

20 dB for 850 nm over 62.5/125
22 dB for 1310 nm over 9/125
28 dB for 1310 nm or 1550 nm laser over 9/125

Alarm

Operation

Normally Open and Normally Closed, using different pins

Connector

15-pin, D-type, female

Indicators

POWER

ON – The unit is powered

TEST LOC

ON – The unit is in local loopback mode

TEST REM

ON – The unit is in remote loopback mode

ELECTRICAL LOW

ON – The electrical interface input is below G.703

electrical levels

ELECTRICAL AIS

ON – An “All 1s” string is received at the electrical

interface

OPTICAL ERR

ON – Bit error rate of the received signal from the optical

interface is 10

-6

or worse

OPTICAL AIS

ON – An “All 1s” string is received at the optical interface