(2) Errors Occur When the Emulator Debugger Starts Up

(When the target system is connected)

Table 6.2 Checkpoints of errors when starting up the emulator debugger (target connected)

Error

Communication error occurred
Data was not sent to the target

Target system cannot be properly built

M3T-PD30 version is not the same version
as the firmware in the target

Target MCU is in the reset state

Target MCU cannot be reset

Target is in HOLD state

Target clock is stopped

Target MCU is not receiving power

Checkpoint

Check all emulator debugger settings, interface cable
connection and switches on the rear of the PC4701 match.

See the instruction manuals of the PC4701 and the
emulator debugger.

(1) Download the proper firmware.

See "4.2 Downloading Firmware" (page 38).

(2) Recheck the connection between the PC4701 and

this product.

See "3.5 Connecting the PC4701 and Emulation
Pod" (page 30).

Download the firmware in the maintenance mode.

See "4.2 Downloading Firmware" (page 38).

(1) Check the reset pin in the target system is pulled up.
(2) Check the reset pin of the target system has changed

from "Low" to "High" level.

(1) If the reset circuit of the target system has a watchdog

timer, disable the timer.

(2) Check power is properly supplied to the target system

and that the target system is properly grounded.

(3) The program may be uncontrollable in areas where

memory not allocated. Recheck the map setting.

See "1.1 Notes on MAP References and Settings"
(page 13).

(1) The MCU is either in the stop mode or wait mode.

Either reset the MCU or cancel the mode with an
interrupt.

See the MCU specifications.

(2) The program may be uncontrollable in areas where

memory not allocated. Recheck the map setting.

See "1.1 Notes on MAP References and Settings"
(page 13).

Check the oscillation circuit of the target system is
oscillating properly.

Check power is properly supplied to the target system
and that the target system is properly grounded.