37

Technical Data

This cooker is designed for use on either :-

NATURAL GAS (Cat I2H ) at 20mbar or

LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.

NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT
MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.

Country of Destination: GB

Gas

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

Propane

37mbar

(See appliance data badge for test pressures)

Dimensions

Overall height including optional splashback

minimum 1060mm

maximum 1090mm

Overall height

minimum 893mm

maximum 920mm

Overall width

900mm See ‘Positioning of Cooker’

Overall depth

648mm

Space for fixing

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

Connections

Gas:

Electric

Rp

1

/

2

at rear right-hand side

220 - 240V 50Hz

Ratings

Natural Gas

L.P. Gas

Hotplate

Injector

Injector

Wok burner

3.5kW

internal 80

3.5kW (246g/h)

internal 54

external 129

external 77

Large Burner

3.0kW

134

3.0kW (210g/h)

87

Medium Burners

1.7kW

109

1.7kW (119g/h)

68

Small Burner

1.0kW

75

1.0kW (70g/h)

51

Main Oven

3.2kW

237

2.9kW (224g/h)

85

Grill

2.73kW

190

2.73kW (192g/h)

85

Gas burner inputs based on Gross Calorifi c Value

Tall Oven

Forced air convection

2.5kW

Energy effi ciency class on a scale of A (more effi cient) to G (less effi cient)

B

Energy consumption based on standard load

0.95kWh

Usable volume (litres)

53

Size

Medium

Maximum total electrical load at 230V 2.6kW (approximate total including oven light, oven fan etc.)