3 selecting clock supply, Important – Renesas Emulation Pod M30620T2-RPD-E User Manual

Page 31

Advertising
background image

( 29 / 78 )

3.3 Selecting Clock Supply

There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.3 lists the factory-settings of each clock
supply.

Table 3.3 Clock supply to the MCU

Clock

Description

Display of emulator debugger

Default setting

X

IN

-X

OUT

X

CIN

-X

COUT

Internal oscillator circuit of emulation pod

(OSC-3: 16 MHz)

Target System

Internal oscillator circuit of emulation pod

(32.768 kHz)

Target System

Internal

External

External

Internal

O

-

-

O

IMPORTANT

Notes on Changing the Clock Supply:

• The clock supply can be set by the Init dialog when starting up the emulator debugger

or inputting CLK command on the script window.

• For X

CIN

-X

COUT

pins, it is necessary to set switches in the emulation pod. For details,

refer to "3.2 Setting Switches and Pullup Resistor" (page 25).

Advertising