Electronic Ignition Gas Valves

Manual
Shut-Off
Valve

Manometer

Gas Pressure Test at
Gas Valve

Fig. 11: Location of Gas Pressure Adjustment

Pipe Sizing for Gas Connections

Water Connections

The heater requires water flow and positive pressure
to fire and operate properly. It must therefore be
installed downstream of the discharge side of the filter
pump. A typical installation is plumbed as follows:

1. The inlet side of the filter is plumbed directly to the

discharge side of the filter pump;

2. The outlet side of the filter is then plumbed to the

inlet of the heater; and

3. The outlet of the heater is plumbed to the return

line to the pool or spa. The pump, filter and heater
are thus plumbed in series.

Model

No.

Input

(KBTU)

1/2 in.

3/4 in.

1 in.

N

P

N

P

N

P

130A

130

15

35

60

145

200

500

Natural Gas 1000 BTU/FT3 0.60
Specific Gravity @ 0.5 in. WC Pressure Drop
Propane Gas 2500 BTU/FT3 1.53
Specific Gravity @ 0.5 in. WC Pressure Drop

Table E: Maximum Equivalent Pipe Length

Plumbing from the heater back to the pool or spa must
not have any valves or restriction that could prevent
flow when the pump is operating.

Heater must be located so that any water leaks will not
damage the structure of adjacent area. PVC pipe may
be glued directly into optional or field-supplied header
unions.

Flow Rates

Polymer Headers

Before attaching the optional 2-inch unions to the
In/Out header, make sure the O-rings are properly
seated in the grooves. Use AquaLube or equivalent
non-petroleum-based lubricant on the O-ring. Hand
tighten the unions. Glue PVC piping directly to the
unions.

Model No.

Min. gpm

Max gpm*

130A

20

70

*When flow rates exceed maximum 70 gpm, an external auxiliary
bypass valve is required. See External Auxiliary Bypass Valve sec-
tion for details.

Table F: Water Flow Rates

In/Out Header

O-Ring

Tail Piece

Nut

2“ Pipe

Drain Plug

In/Out Header

Hose Connector

Hose

Fig. 12: Optional In/Out Header for 2" Installation

Fig. 13: In/Out Header for 1-1/2" or 1-1/4" Hose

Connection