Control adjustments—millivolt, Installation instructions—240 volt, 240v hook-up – Raypak 130A User Manual

Page 16

Advertising
background image

16

Installation Instructions—240 Volt

1. Disconnect and remove 120 volt power cord.

2. Install wire nut on white transformer wire.

3. Wire nut 240 volt supply lines to the red and black

wire on the transformer.

4. Wire nut green supply ground line to green trans-

former wire

CAUTION: This appliance has provisions to be
connected to an alternate supply source. To reduce
the risk of electric shock, disconnect all connections
before servicing.

240V HOOK-UP

HEATER

L1

L2

RED

RED

BLACK

HOT

HOT

BLACK

GREEN

GREEN

WHITE

SUPPLY

SIDE

Fig. 18: 240V Hook-Up

Control Adjustments—Millivolt

The pool or spa water temperature is controlled by the
thermostat on the upper front panel of the heater. The
control center contains an On/Off toggle switch and a
thermostat. The switch functions as a means for turn-
ing the heater On or Off.

The thermostat is fitted with a means of limiting the
upper temperature limit below the maximum level. The
knob stop adjustment ring shown in Fig. 19 is
adjustable by loosening the set screw, rotating the
knobstop ring to the desired location, and retightening
the set screw.

HOT

COOL

Knobstop Ring

Knobstop Set Screw

Fig. 19: Water Temperature Thermostat

NOTE: Maximum temperature is 104°F.