Raypak 130A User Manual

Page 23

Advertising
background image

23

4. Disconnect gas line from gas valve.

5. Remove (2) screws that mount burner tray to unit,

and (2) screws that secure gas valve to jacket.

6. Disconnect wires that terminate at gas valve.

7. Disconnect hi-tension wire from igniter.

8. Remove (1) screw that mounts ground wire to

burner tray.

9. Slide out burner tray.

10. Reverse above procedure to reinstall.

Rear Hold Down Bracket

Burner

Millivolt Pilot Assembly
(under Pilot Shield)

Millivolt Gas Valve
(Invensys shown)

Manifold

Pilot Lighter Tube

Orifice Placement Bracket

Pilot Bracket

Burner Tray Panel

Orifice

Pilot
Shield

Rear Hold Down Bracket

Burner

DSI Gas Valve
(Honeywell shown)

Manifold

Orifice Placement Bracket

Burner Tray Panel

Orifice

Igniter

Fig. 29: Millivolt Burner Tray Assembly

Fig. 30: DSI Burner Tray Assembly