Raypak 130A User Manual

Page 29

Advertising
background image

29

Terminal Block Wiring

Fig. 36: Terminal Block Wiring

1. Raw Output (700mV± 100)

Pilot generator disconnected from valve (knob must be held down to keep pilot on).
White – Negative
Red + Positive

2. Pilot Load (500mV± 100)

Pilot generator connected to valve-Power applied to pilot solenoid.
TP(Thermopile-Robertshaw)
PP(Power Pile-Honeywell)
TH TP – Common (Invensys)
TH PP – Common (Honeywell)

3. Main Valve Load (200mV± 100)

Control/Limit circuit closed (All switches "ON")
TP(Thermopile-Robertshaw)
PP(Power Pile-Honeywell)
TH TP – Common (Invensys)
TH PP – Common (Honeywell)