2 led function – Oki POS 425S User Manual

Page 32

Advertising
background image

32

OKIPOS 425S

|

2.1.2 LED Function

A25004.doc

No.

LED

ON

OFF

Blinking

1

POWER

Green

Powered On

Powered off

-

2

LED 1

(ERROR)

Red

Recoverable Alarms
*Slip Feed/Eject Alarm
*Auto Loading Alarm
*Auto Parking Alarm
*Media Mismatch
Alarm (1)
*Media Mismatch
Alarm (2)
*Cover Open Alarm
(Only OKI standard
type)

Normal state

*Unrecoverable Alarms
(blinking pattern indicates
alarm type)
*See the table in section 4.1
*SP Thermal alarm
(LED2 blinks concurrently)
*LF Thermal Alarm

3

LED2
(Status)

Orange

Paper is not fed
(In sheet-insertion wait
state)

Paper has been
fed
(in print ready
state)

*In sheet-extraction wait
state
*SP Thermal Alarm
(LED1 blinks concurrently)

Orange

In Slip Mode

In
Validation
mode
*Quick
blinking

In MICR
Mode
*Slow
blinking

4

LED3/
LED4
(Mode)

Green

In Receipt Mode

In Tractor
Mode

-

When “Cover Open Alarm” is set to No in Menu, Cover Open Alarm is disabled (printing does not stop).

* Media Does Not Match Alarm (1) is detected by monitoring the option tractor lever. Media Does Not
Match Alarm (2) is detected by the Validation sensor monitoring (media manually inserted into the
validation opening).

Advertising