Warning, F. horizontal termination – OmniTek TOPAZ 839-1340 User Manual

Page 12

Advertising
background image

12

Quadra-Fire • Topaz • 7009-113 Rev. N • 5/13

Female Locking Lugs

Male Locking Lugs

Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.

F. Horizontal Termination

Figure 5.4

Figure 5.3

(See Section 12 for conversion kit and venting
components.) This is the only venting configuration that
requires the use of the rear vent derating orifice that
comes with the rear vent kit.

NOTE: A Snorkel Kit is

required.

Rear Installations for Use with Rear Vent
Kit

Type B -

Up & Out Installations for Top Vent
Configurations

Type A -

90º Degree
Elbow

Pipe Length

Pipe Length

Wall Thimble Cover

Termination Cap

Wall Thimble

Wall Thimble Cover

Pipe Length

Wall Strap
14 in. (356mm) Wide

C

L

21 in.
(533mm)

Wall Thimble

Snorkle Kit

15-5/8 in.
(397mm)

Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are
designed to slide straight onto the male ends of adjacent
pipes by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see

Figure 5.4.

Push the pipe sections completely together, then twist-lock
one section clockwise approximately one-quarter turn, until
the two sections are fully locked. The female locking lugs
may not be visible from the outside. They may be located by
examining the inside of the female ends.

Fire Risk.

Explosion Risk.

Combustion Fume Risk.
Use vent run supports per installation instructions.

Connect vent sections per installation instructions.

• Maintain all clearances to combustibles.

• Do NOT allow vent to sag below connection

point to appliance.

• Maintain specifi ed slope (if required).

WARNING

Improper support may allow vent to sag or separate.

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

WARNING

• Ensure vent components are locked together correctly.

• Pipe may separate if not properly joined.

Advertising