4. Existing Masonry Chimney

Type A - Up & Out Installations for Top Vent
Configurations

Figure 5.24

Type B - Hearth Rear Vent Installations for Use With
Rear Vent Kit
(see Section 12 for conversion kit and
venting components.)

Chimney Liner

Termination Cap

Co-Axial to

Co-Linear Connector

3 in. (76mm)

Flex Liner

Pipe Length

Optional

Chimney Liner

Termination Cap

Co-Axial to

Co-Linear

Connector

30 ft. (9m) of 3 in.

(76mm) Flex Liner

Exhaust Section

Pipe Length

Optional

4 ft. (1m) of 3 in.

(76mm) Flex Liner

Air Intake Section

The chimney must be sealed
from the 4 ft. (1m) section to
termination using a smoke
shelf or a damper.
The seal should be 6 in.
(152mm) below the end of the
4 ft. (1m) Air Intake section.

This section of the
chimney must be
sealed

Termination Cap

Flashing

4 in. (102mm)

Flex Liner

Top Adaptor

Retro Connector

90° Elbow

Direct Vent Pipe

Advertising