OmniTek TOPAZ 839-1340 User Manual

Page 22

Advertising
background image

22

Quadra-Fire • Topaz • 7009-113 Rev. N • 5/13

High Wind
Termination Cap

Top Adaptor

(3) Sheet Metal Screws

Flashing

Step 9.
Attach the flex to the retro connector. Use three sheet metal
screws to attach the flex liner to the connector (

Figure

5.29). Mount the retro connector to the masonry wall using
masonry bolts. Redrill larger holes on connector as needed.
Be careful to ensure that the connector is centered in the
opening and the mounting holes line up with the masonry
wall.

6 in. (152mm) diameter
opening in masonry wall

(3) Masonry Bolts
(Not included)

Retro Connector

(4) Masonry Bolts

(Not included)

Retro Connector

Wall Thimble Cover

Step 8.
Secure the top adapter to the flashing. Use three sheet
metal screws through the side of the top adapter into the
flange on the flashing (

Figure 5.28). Twist lock the high

wind termination cap on to the top adapter.

Figure 5.28

Flex Liner

Flex Coupler

Sheet Metal Screws

Figure 5.27

Figure 5.29

Figure 5.30

Step 10.
Slide wall thimble cover over retro connector and secure
with masonry bolts (

Figure 5.30). If you have a framed wall

in front of the masonry, use wood screws to mount wall
thimble cover to framed wall, over retro connector and 10
in. (254mm) square framed opening (

Figure 5.25, on page

21). If needed, add a section of direct vent pipe to the retro
connector in order to extend through the opening in the wall
thimble cover.

Step 11.
The connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.

Advertising
This manual is related to the following products: