3 - 3

3 TRANSMITTING FUNCTIONS

3.2.2 Output Format of Measured Values in Binary Mode

When the TS0, ESC T and FM1 commands are received, the measured values and
computed results are output in binary.

Output format:

(1) Sequence of transfer

1

2

3

4

5

6

Byte

Number of bytes
sent (2 bytes)

Date and time (6 bytes)

Measured data 1 (5 bytes)

Measured data n (last) (5 bytes)

(2) Number of bytes sent

Number of bytes sent = 5

×

n + 6

This parameter can be sent either from the most significant byte or from the least
significant byte, as specified by the BO command.
Note that the 2 bytes of the “number of bytes sent” itself are not included.

(3) Date and time

1

2

3

4

5

6

Year

Month

Day

Hour

Minute

Second

Byte

Year :

Month :

Day :

Hour :

Minute :

Second :

0 to 99 (00H to 63H)

1 to 12 (01H to 0CH)

1 to 31 (01H to 1FH)

0 to 23 (00H to 17H)

0 to 59 (00H to 3BH)

0 to 59 (00H to 3BH)

3.2 Output Data Formats