7 - 3

7 PROGRAM EXAMPLES

7.3 Program to Read Unit and Decimal Point Information from VR200,

Display It on Screen, and Write It to Disk

100

‘**********************************************************

110

‘** RS422A Example Program for IBM PC **

120

‘** **

130

‘** To input and save point and unit information **

140

‘** **

150

‘**********************************************************

160

‘**

170

‘** Baud rate: 1200

Stop bit: 1 bit

180

‘** Parity: none

Control: OFF/OFF

190

‘** Data length: 8 bits

Others: LF is sent automatically.

200

‘**

210

220

OPEN “COM1:1200,N,8,1,LF” AS #1

230

OPEN “TEST.DAT” FOR OUTPUT AS #2

240

250

LF$=CHR$(&HA)

:’ Line feed = 0AH

260

PRINT #1,CHR$(27)+”O 01"

270

PRINT #1,”TS2"

280

PRINT #1,CHR$(27)+”T”;

290

PRINT #1,”LF01,04"

300

LINE INPUT #1,D$

310

IF LEFT$(D$,1)=LF$ THEN D$=MID$(D$,2) :’ Remove “LF” of head string

320

PRINT D$

330

PRINT #2,D$

340

IF MID$(D$,2,1)<>”E” THEN GOTO 300

350

360

PRINT #1,CHR$(27)+”C 01"

370

CLOSE

380

END

7.3 Program to Read Unit and Decimal point Information from VR200, Display It on Screen, and Write It to Disk