Setup for rate monitor, Setup for high and low frequency monitor – Omega Engineering DP3300 Series User Manual

Page 20

Advertising
background image

DP3300 Series User’s Manual

Page19

FUNCTION

DISPLAY SHOWS

TO CHANGE


active digit flashing.

active digit.


Division Factor

'dIV FAC' followed by preset

Push ^v key to increment or decrement

division

factor

e.g.

12 with

active digit. Push <NXT> key to

active

digit

flashing.

change

active

digit.

Limit 1

'CH1 LT1' followed by preset Limit 1

Push ^v key to increment or decrement

Limit

2

value

e.g.

123.4 with active digit

active digit. Push <NXT> key to

Limit

3

flashing.

active

digit.

For

limits

2

&3

CH1 LT2, CH1 LT3

NOTE: Limit3 is audio visual alarm only

followed by limit value.

--- it has no relay output.


Relay deadband

'dEAdbd' followed by deadband

Push ^v key to increment or decrement

value e.g. 0002

active

digit.

Push

<NXT> key to make

next digit active.


Latching or non -

'LATCH' for latching mode.

Push ^v key to obtain alternate mode.

latching relay setup.

'NON LCH' for non- latching mode.


Limit outputs prog-

LT1 N.O. or LT1 N.C

Use ^V key to obtain

rammed as normally

LT2 N.O. or LT2 N.C

alternate

mode.

open or closed

LT3 N.O. or LT2 N.C

Time base for RATE

'T BASE' followed by previously

Push ^v key to increment or decrement active

calculation (In seconds)

programmed value e.g. '1.999'

digit. Push <NXT> key to make next digit active


SETUP FOR HIGH AND LOW FREQUENCY MONITOR:

If the unit is setup as a frequency meter, then following SETUP steps are performed.

FUNCTION

DISPLAY SHOWS

TO CHANGE



Scaler

'SCALER' followed by preset scaler

Push ^v key to increment or decrement

value e.g. 10.00024 with active digit

active digit. Push <NXT> key to

flashing.

change active digit.


Division Factor

'DIV FAC' followed by preset division

Push ^v key to inc rement or

decrement

by preset division factor. (e.g. 12`

active digit. Push <NXT> key to

with

active

digit

flashing).

change

active

digit.


Limit 1

'CH1 LT1' followed by preset Limit 1

Push ^v key to increment or decrement

Limit

2

value

e.g.

123.4 with active digit

active digit. Push <NXT> key to

Limit

3

flashing.

active

digit.

For

limits

2

&3

CH1 LT2, CH1 LT3

NOTE: Limit3 is audio visual alarm only

followed by limit value.

--- it has no relay output.


Relay deadband

'dEAdbd' followed by deadband

Push ^v key to increment or decrement

value e.g. 0002

active

digit.

Push

<NXT> key to make

next digit active.


Advertising