Table 6-1 rpm mode, Key display action taken shows and procedure – Omega Speaker Systems OMEGAFLEX FPU5-MT-220 User Manual

Page 40

Advertising
background image

6-3

Table 6-1

RPM MODE

KEY

DISPLAY

ACTION TAKEN

SHOWS

AND PROCEDURE

xxx rpm

Pump motor’s power

NOTE: if you turn off the pump motor’s power, the pump stops

running.

To continue pumping, turn on the unit’s power. The display
returns to the STOPPED Display Mode and shows the current
RPM setting. The accumulated time of pumping and volume
dispensed is reset to zero. Then press the START/STOP key.

ON/OFF Switch

xxx rpm

Pump(s) stops; press again pump(s) starts

To resume pumping at the current setting, press the
START/STOP key. The display enters the RUNNING Display
Mode
, and the fluid begins to dispense.

START

STOP

Must STOP first!

LEDs indicate new pump direction

To select the other inlet and reverse the direction of pumping:
1.

Press the START/STOP key. The display returns to the
STOPPED Display Mode.

2.

Press the INLET SELECT key to reverse the direction of
pumping.

3.

Press the START/STOP key again to resume pumping.

4.

For detailed instructions on “Defining the Direction of
Pumping, refer to Section 5.2.

STOP to Prime...

Pumps fluid at current RPM setting as long as the key is pressed

To prime a tube:
1.

Press the START/STOP key to stop the pump. The display
returns to the STOPPED Display Mode.

2.

Press and hold down the PRIME key to prime the tube.

3.

Press the START/STOP key again to resume pumping.

4.

For detailed instructions on “Priming a Tube”, refer to Section
5.4.

INLET

SELECT

PRIME

xxx °C

Display alternates when pressed, °C then °F

NOTE: The TEMP key functions the same whether the pump is

stopped or running. Refer to Section 5.6.

TEMP

RPM

xxx rpm

Displays current RPM setting

1.

Press the RPM key. The display flashes the RPM setting
you selected just before starting the pump.

2.

Use the UP and DOWN ARROW keys to enter the RPM
setting you desire. As you use the UP and DOWN ARROW
keys
, the display changes accordingly.

TIME

xx:xx:xx

Displays cumulative TIME since start

Press the TIME key. The display flashes the time that the pump
has been running (xx:xx:xx).

Advertising