MAIN SPECIFICATIONS

Model Number

: FS-FL36

Type

: External electronic flash for digital still camera

Guide number

: Automatic switching

36: When in 42 mm (85 mm with 135 type)
20: When in 12 mm (24 mm with 135 type)
8/10 switching: When the wide panel is used.

Firing angle

: Automatic switching.

At 12 mm: Up-down 61°, left-right 78°(equivalent to image angle of 12 mm lens)*
At 42 mm: Up-down 21°, left-right 28°(equivalent to image angle of 42 mm lens)*
When the wide panel is used for 8 mm: Up-down 83°, left-right 101°
(equivalent to image angle of 8 mm lens)*
* ZOOM values are the FOUR THIRDS camera values.

Flash emission period

: Approx. 1/20000 to 1/500 sec. (Variable according to the light intensity, except in FP

emission.)

Flash emission count

: Approx. 150 times (using the LR6-type AA (R6) alkaline dry cell batteries)

(at full activation)

Approx. 320 times (using the LB-01 type lithium battery packs)
(Variable depending on shooting conditions)

Recharge time

: Approx. 7.5 seconds (using the AA (R6) alkaline manganese batteries)

(from full activation to

Approx. 6.5 seconds (using the LB-01 type lithium battery packs)

charge lamp lighting)
Flash modes

: TTL AUTO, AUTO, MANUAL, FP TTL AUTO, FP MANUAL

Bounce angles

: Up 0 to 90°, down 7°, right 0 to 90°, left 0 to 180°

Auto power OFF

: Interlocks with the auto power OFF operation of a camera with communication capa-

bility

Q

When the Olympus E-1 digital camera enters the sleep mode, the FL-36 control panel displays
turn off. Is this normal?

A

Yes, it is normal. When the E-1 enters the sleep mode, the FL-36 does as well. When the camera
wakes up, so does the FL-36.

Q

Does the FL-36 also turn off when the Olympus E-1 digital camera is turned off?

A

When the E-1 is turned off, the FL-36 enters the sleep mode. When the E-1 is turned on again, the
FL-36 also turns on. When you want to turn off the FL-36, turn off the FL-36 before turning off the
E-1. In addition, when connected to a camera without communication capability, the FL-36
enters the sleep mode if it is not operated for about 15 minutes.