4. ethernetinterface model – Oki RT322POS User Manual

Page 48

Advertising
background image

– 44 –

No. 1 2 3 4 5 6 7 8

No. 1 2 3 4

9 10

DIP-SW 1

DIP-SW 2

10-4. EthernetInterface Model

ON

ON

OFF

OFF

DIP-SW

1

Switch 1-1

Switch 1-2

Command emulation

ON

ON

Star Line Mode

OFF

ON

Star Page Mode

ON

OFF

-

OFF

OFF

ESC/POS Mode

The factory settings of DIP switch are all on.

The functions of switches 1-3 through 1-10 will change according to the command emulation

that has been set using switch 1-1 and 1-2.

(1) Star Line Mode

Switch

Function

ON

OFF

1-1

Command emulation

Always ON

1-2

Command emulation

Always ON

1-3

Should not be changed (Should be set to on)

1-4

Sensor adjustment

Invalid

Valid

1-5

Should not be changed (Should be set to on)

1-6

Handshaking conditions

(conditions for BUSY)

Offline or receive

buffer full

Receive buffer full

1-7

ASB function *1

Valid

Invalid

1-8

NSB function *2

Valid

Invalid

1-9 ~1-10

Should not be changed (Should be set to on)

2) Star Page Mode

Switch

Function

ON

OFF

1-1

Command emulation

Always OFF

1-2

Command emulation

Always ON

1-3

Should not be changed (Should be set to on)

1-4

Sensor adjustment

Invalid

Valid

1-5

Should not be changed (Should be set to on)

1-6

Handshaking conditions

(conditions for BUSY)

Offline or receive

buffer full

Receive buffer full

1-7

ASB function *1

Valid

Invalid

1-8

NSB function *2

Valid

Invalid

1-9 ~1-10

Should not be changed (Should be set to on)