Omega 3200ST User Manual

Page 13

Advertising
background image

M-4271/0707, pg. 13 of 26

f) Using a 0-5VDC Input / Output Power Adapter Package.


An optional 0-5VDC Input / Output Power Adapter Package is available for

use with the FMA 3200/3400 Series. This consists of a power source

(115VAC or 230VAC), a connection hub and two cable assemblies with pig-

tail (soldered wire) ends. This should be assembled as shown in the

following diagram.

Assembling a FMA 3215PW Power Adapter Package

(the FMA 3223PW Power Adapter Package is similar)

The RED connector should be inserted in the RED socket on the

connection hub. The WHITE connector should be inserted in the WHITE

socket on the connection hub.


The cable with a RED connector provides the input signal. The RED wire

of this cable should be connected to the positive terminal of the voltage
source. The (0-5VDC) voltage control signal should be supplied from a low

impedance source. The bare wire of this cable assembly is the input
signal negative (ground) and should be connected to the negative

(Ground) terminal of the voltage source.


The cable with a WHITE connector provides the signal output. The

WHITE wire should be connected to the positive terminal of the display,
data acquisition system or voltmeter with an impedance of greater than

2.5 kΩ (kilo ohms). The bare wire of this cable assembly is the signal

negative (ground) and should be connected to the negative (Ground)

terminal of the display, data acquisition system or voltmeter.

Caution: Avoid high voltage static discharges to the input signal

connection. Do not short the output signal wires or allow them to
contact the power wires at any time. DAMAGE WILL RESULT!