DISPLAY

DESCRIPTION

FACTORY

Sunday

Monday

Saturday

Friday

Thursday

Wednesday

Tuesday

TIME-OUT VALUE

to

ª

«

ª

«

TIMER STOP

ª

«

SETPOINT POWER-UP STATE

Determines the on/off state of the Setpoint output at power-up. Regardless of

output logic setting (normal or reverse).

Deactivates the Setpoint output at power-up

Activates the Setpoint output at power-up

Restores the output to the state it was in prior to power-down

Timer stops when the Setpoint output activates (

) or deactivates (

).

Select

if the output should not affect the Timer Run/Stop status.

Stopping the Timer as a result of this parameter does not constitute a

condition (event) for the Setpoint On or Setpoint Off parameters.

This parameter only appears when the Setpoint is assigned (

) to the

Real-Time Clock Time display (

). This parameter determines the days of

the week when the Setpoint output will activate.

Selecting

displays a sublist for choosing the days of the week. On all

days entered as

in the sublist, the output will activate. On all days entered

as , the output will not activate. The output activation is repetitive, and will
occur every week on the chosen day(s).

ª

«

This parameter only appears when the Setpoint is assigned (

) to the

Real-Time Clock Time display (

) and when the Setpoint Action (

)

is programmed for On-Off Output mode (

). In this mode, this parameter

determines the days of the week when the Setpoint output will deactivate.

Selecting

displays a sublist for choosing the days of the week. On all

days entered as

in the sublist, the output will deactivate. On all days entered

as , the output will not deactivate. The output deactivation is repetitive, and
will occur every week on the chosen day(s).

ª

«

The Time-Out Value only appears when the Setpoint Action (

) is

programmed for Timed Output mode (

). In this mode, the Time-Out Value

is the Setpoint Output time duration, from activation to deactivation. This value
is always entered in minutes, seconds, and hundredths of seconds format. The
maximum Time-Out Value is 99 minutes 59.99 seconds.

ª

«

TIMER/COUNTER AUTO RESET

When the Setpoint output activates (

) or deactivates (

), the meter

automatically resets the Setpoint Assignment display (

). Select

if the

Setpoint output should not cause the assigned display to reset. Does not apply
to manual activations or deactivations by user input, function key, or serial
communications.

ª

«

OUTPUT RESET WITH DISPLAY RESET

When

is selected, the Setpoint output will reset when the Setpoint

Assignment display (

) resets. Select

if the Setpoint output should not

reset when the assigned display resets.

ª

«

SETPOINT ANNUNCIATOR

This parameter controls the illumination of the LED annunciator for the

corresponding Setpoint output (

) as follows:

Saturday

Friday

Thursday

Wednesday

Tuesday

Monday

Sunday

FACTORY

DESCRIPTION

DISPLAY

Normal (

) –

Annunciator displayed when output is “on” (activated)

Reverse (

) –

Annunciator displayed when output is “off” (deactivated)

Flash (

) –

Annunciator and display flashes when output is “on” (activated)

Off (

)

Annunciator disabled

Setpoint One-Shot Mode

If all days are set to , the Setpoint will operate in “One-shot” mode. When

a One-shot setpoint is enabled (armed), the setpoint output will activate at the
set time and disable itself from activating again. To enable or re-enable a one-
shot alarm, go to the Setpoint value entry display and press the Up or Dn key
repeatedly while the AM/PM digit is selected (flashing). When the 2nd digit
decimal point is lit, the Setpoint is enabled. The Setpoint enable status is saved
at power-down. The enable state of the Setpoint is not affected or changed when
the Parameter List is exchanged.

The setpoint will turn off (de-activate) as programmed per the Setpoint

Action selected. If

mode is selected, program all the Daily Off days to

to have the Setpoint turn off at the next Daily Off Occurrence. The One-

shot status can also be viewed or set from the Setpoint Off value entry display.

PTC901: DAILY OFF OCCURRENCE

PTC901: DAILY ON OCCURRENCE