2 timer input wiring, 1 power wiring, 3 user input wiring – Omega Vehicle Security PTC900 User Manual

Page 8

Advertising
background image

8

Before connecting the wires, the Timer Input logic jumper should be verified for proper position.

4.2 TIMER INPUT WIRING

CAUTION: Timer Input common is NOT isolated from User Input common. In order to preserve the safety of the meter application, the timer input
common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not,
hazardous voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the potential
of the User Input Common with respect to earth ground; and the common of the isolated plug-in cards with respect to input common.

Two Wire Proximity, Current Source

Current Sourcing Output

Interfacing With TTL

Current Sinking Output

Switch or Isolated Transistor; Current Sink

Switch or Isolated Transistor; Current Source

Emitter Follower; Current Source

4.1 POWER WIRING

AC Power

Terminal 1: VAC
Terminal 2: VAC

DC Power

Terminal 1: +VDC
Terminal 2: -VDC

4.3 USER INPUT WIRING

Before connecting the wires, the Timer Input logic jumper should be verified for proper position. When the user input is configured for cycle

count, in module 4, the count input should be wired between terminals 7 & 10.

Sourcing Logic

Terminals 7-9:

+ VDC through external switching device

Terminal 10:

-VDC through external switching device

The user inputs of the meter are internally
pulled down to 0 V with 22 K

Ω resistance.

The input is active when a voltage greater
than 3.6 VDC is applied.

Sinking Logic

Terminals 7-9
Terminal 10

The user inputs of the meter are internally
pulled up to +12 V with 22 K

Ω resistance.

The input is active when it is pulled low
(<0 .9 V).

Connect external switching device between the
appropriate User Input terminal and User Comm.

}