Baud, 9600 data, 7par – Omega Vehicle Security PTC900 User Manual

Page 28: Odd addr, 00 abbr, Yes opt, T-dsp, Yes c-dsp, No rtc-d, No rtc-t

Advertising
background image

28

7-SrL

Serial Communication Parameters

DISPLAY

PARAMETER

FACTORY

SETTING

USER SETTING

bAUd

BAUD RATE

9600

dAtA

DATA BITS

7

PAr

PARITY BIT

Odd

Addr

METER UNIT ADDRESS

00

Abbr

ABBREVIATED PRINTING

NO

REAL-TIME CLOCK PRINT FORMAT

YES

OPt

PRINT OPTIONS

t-dSP

TIMER DISPLAY

YES

C-dSP

CYCLE COUNTER DISPLAY

NO

rtC-d

RTC DATE DISPLAY

NO

rtC-t

RTC TIME DISPLAY

NO

spNt

SETPOINT VALUES

NO

SPNtOF

SETPOINT OFF/ TIME-OUT VALUES

NO

PARAMETER

USER SETTING

FACTORY

SETTING

dSP-t

12-59p

dSP-d

DATE DISPLAY FORMAT

12-31

SyNC

Ch-dSt

sLAVE

N0

OFFSEt

CAL

00

TIME DISPLAY FORMAT

DISPLAY

AUTO TIME CHANGE FOR D.S.T.
SYNCHRONIZATION UNIT TYPE
CALIBRATE REAL-TIME CLOCK
RTC CALIBRATION OFFSET VALUE

9-fCS

Factory Service Parameters

DISPLAY

DISPLAY INTENSITY LEVEL

3

d-LEV

FACTORY

SETTING

USER SETTING

PARAMETER

Shaded areas are model dependent.

Shaded areas are model dependent.

8-rtC

Real-Time Clock Parameters

OUt-n

tOUt-n

SPOF-n

OFF-n

SP-n

ON-n

ASM-n
ACt-n

DISPLAY

NOr

NOr

NOr

NOr

SETPOINT ANNUNCIATOR
POWER-UP STATE

NO

NO

NO

NO

OUTPUT RESET W/DISPLAY RESET

NO

NO

NO

NO

TIMER/COUNTER AUTO RESET

NOr

NOr

NOr

NOr

OUTPUT LOGIC

VALUE

VALUE

VALUE

000100

000100

000100

VALUE

000100

VALUE

VALUE

000100

000100

000100

SETPOINT OFF VALUE (B)*

VALUE

SETPOINT OFF (B)*

TIME-OUT VALUE (B)*

TIME-OUT VALUE (A)

000100

SETPOINT OFF VALUE (A)

VALUE

SETPOINT OFF (A)

LAtCH

LAtCH

LAtCH

VALUE

NO

Mon-Fri

Mon-Fri

Mon-Fri

Mon-Fri

000000

000000

VALUE

VALUE

NONE

SP-4

USER SETTING

NO

Mon-Fri

Mon-Fri

Mon-Fri

Mon-Fri

000000

000000

VALUE

NONE

SP-3

LAtCH

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

VALUE

NO

Mon-Fri

Mon-Fri

Mon-Fri

Mon-Fri

000000

000000

VALUE

VALUE

SETPOINT ON (B)*

NONE

SP-2

SETPOINT ACTION

USER SETTING

NO

TIMER STOP

Mon-Fri

DAILY OFF OCCURRENCE (B)*

Mon-Fri

DAILY OFF OCCURRENCE (A)

Mon-Fri

DAILY ON OCCURRENCE (B)*

Mon-Fri

DAILY ON OCCURRENCE (A)

000000

SETPOINT ON VALUE (B)*

000000

SETPOINT ON VALUE (A)

VALUE

SETPOINT ON (A)

NONE

SETPOINT ASSIGNMENT

SP-1

6-SPt

Setpoint (Alarm) Parameters

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

PARAMETER

PTC901 Application

A big application request has always been for

Real-Time Clocks to display time throughout the
plant. The challenge has been to keep all the
various clock locations synchronized with the
right time. With the new PTC901 Timer/Real-
Time Clock this problem is history. You can install
up to a maximum of 32 units. Simply select one of
the units in the system as the host and the balance
are programmed as slaves. The host will send out
a synchronization pulse every hour to correct the
time on any clock unit wired in the system.

Real-Time Clock Synchronization Network

* See Module 2, Exchanging Parameter Lists, for details on programming this value.