Able, Ontents, Eneral – Omega Vehicle Security PTC900 User Manual

Page 4: Eter, Pecifications

Advertising
background image

4

General Meter Specifications. . . . . . . . . . . . . 4
Optional Plug-In Cards and Accessories . . . . 5
Installing the Meter . . . . . . . . . . . . . . . . . . . . 6
Setting the Jumpers . . . . . . . . . . . . . . . . . . . 6
Installing Plug-In Cards . . . . . . . . . . . . . . . . . 7

Wiring the Meter . . . . . . . . . . . . . . . . . . . . . . 7
Reviewing the Front Buttons and Display . . 10
Programming the Meter. . . . . . . . . . . . . . . . 11
Factory Service Operations . . . . . . . . . . . . . 26
Programming Overview. . . . . . . . . . . . . . . . 29

T

ABLE

O

F

C

ONTENTS

G

ENERAL

M

ETER

S

PECIFICATIONS

1.

DISPLAY: 6 digit, 0.56" (14.2 mm) red sunlight readable or standard green

LED

2. POWER:

AC Versions (PTC901, PTC900):

AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working)

DC Versions (PTC901-LV, PTC900-LV):

DC Power: 11 to 36 VDC, 14 W
(Derate operating temperature to 40°C if operating <15 VDC and three

Plug-in cards are installed)

AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working)

3. SENSOR POWER: 12 VDC, ±10%, 100 mA max. Short circuit protected.
4. ANNUNCIATORS:

5. KEYPAD: 3 programmable function keys, 5 keys total.
6. TIMER DISPLAY:

Timer Range: 23 Selectable Ranges
Timing Accuracy: ± 0.01%
Minimum Digit Resolution: 0.001 Sec.
Maximum Least Significant Digit Resolution: 1 Hr.
Maximum Display: 999999

7. CYCLE COUNTER DISPLAY:

Counter Range: 0 to 999999
Digit Resolution: 1 cycle
Maximum Count Rate: 50 Hz

8. REAL-TIME/DATE DISPLAY (PTC901):

Real-Time Display: 5 display formats

Hr/Min/Sec (12 or 24 Hr. format); Hr/Min (24 Hr.); Hr/Min (12 Hr. with

or without AM/PM indication)

Date Display: 7 display formats

Month/Day or Day/Month (numeric or 3-letter Month format);

Month/Day/Year or Day/Month/Year (all numeric);

Day of Week/Day (3-letter Day of Week format)

9. REAL-TIME CLOCK CARD: Field replaceable plug-in card

Time Accuracy: ± 5 secs./Month (1 min./year) with end-user calibration
Battery: Lithium 2025 coin cell
Battery Life Expectancy: 10 yrs. typical
Synchronization Interface: Two-wire multi-drop network (RS485 hardware),

32 units max., operates up to 4000 ft.

Isolation To Timer & User Input Commons: 500 Vrms for 1 min.

Working Voltage: 50 V. Not isolated from all other commons.

10. TIMER INPUTS A and B:

Logic inputs configurable as Current Sinking (active low) or Current

Sourcing (active high) via a single plug jumper.

Current Sinking (active low): V

IL

= 0.9 V max., 22K

Ω pull-up to +12 VDC.

Current Sourcing (active high): V

IH

= 3.6 V min., 22K

Ω pull-down, Max.

Continuous Input: 30 VDC.

Timer Input Pulse Width: 1 msec min.
Timer Start/Stop Response Time: 1 msec max.
Filter: Software filtering provided for switch contact debounce. Filter

enabled or disabled through programming.
If enabled, filter results in 50 msec start/stop response time for successive
pulses on the same input terminal.

11. USER INPUTS: Three programmable user inputs

Logic inputs configurable as Current Sinking (active low) or Current

Sourcing (active high) through a single plug jumper.

Current Sinking (active low): V

IL

= 0.9 V max., 22K

Ω pull-up to +12 VDC.

Current Sourcing (active high): V

IH

= 3.6 V min., 22K

Ω pull-down, Max.

Continuous Input: 30 VDC.

Isolation To Timer Input Common: Not isolated
Response Time: 10 msec

12. MEMORY: Non-volatile E

2

PROM retains all programming parameters and

display values.

13. ENVIRONMENTAL CONDITIONS:

Operating Temperature Range: 0 to 50°C (0 to 45°C with all three plug-in
cards installed)
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. RH non-condensing
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z

direction for 1.5 hours, 2 g’s.

Shock According to IEC 68-2-27: Operational 25 g (10g relay), 11 msec in 3

directions.

Altitude: Up to 2000 meters

14. CERTIFICATIONS AND COMPLIANCE:

SAFETY

UL Recognized Component, File # E313607, UL61010A-1, CSA C22.2
No. 61010-1

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File # E313547, UL508, CSA C22.2 No. 14-M95

LISTED by Und. Lab. Inc. to U.S and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical

equipment for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (face only), IEC 529
IP20 Enclosure rating (rear of unit), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Note:

Refer to the EMC Installation Guidelines section for more information.

15. CONNECTIONS: High compression, cage-clamp terminal block

Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.

16. CONSTRUCTION: This meter is rated for NEMA 4X/IP65 outoor use.

IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and
mounting clip included.

17. WEIGHT: 10.1 oz. (286 g)

Power mains class B

Enclosure class B

EN 55022

RF interference

Emissions to EN 50081-1

150 KHz - 80 MHz

Level 3; 10 V/rms

EN 61000-4-6

RF conducted interference

Level 3; 2 Kv power

Level 4; 2 Kv I/O

EN 61000-4-4

Fast transients (burst)

80 MHz - 1 GHz

Level 3; 10 V/m

EN 61000-4-3

Electromagnetic RF fields

Level 3; 8 Kv air

EN 61000-4-2

Electrostatic discharge

Immunity to EN 50082-2

Setpoint 4 Output

SP4 -

Setpoint 3 Output

SP3 -

Setpoint 2 Output

SP2 -

Setpoint 1 Output

SP1 -

Real-Time Clock Time Display

-

Real-Time Clock Date Display

DAT -

Cycle Counter Display

CNT -

Timer Display

TMR -

Advertising