background image

5-2

Section

Connecting to the Host’s RS-422A/485 Port

102

function built in. With the CS1-series and CQM1H, the host link method can be
used by installing a serial communication board. In addition, some C200HX/HG/
HE(-Z)E devices have an integral CPU that can be connected in the host link
method by installing a communication board.

With the CPM2A and CPM2C, an RS-422A type of 1:1 NT Link can be created
through a CPM1-CIF11 RS-422A Adapter.

Check the model and series of the PC and the type of the installed Board or Unit
before making a connection.

The host units featuring the RS-422A/485 type host link function and can be con-
nected to the RS-422A/485 port of the NT31/NT31C are indicated in the table
below.

Units with Built-in Host Link Function

CPUs Connectable with

Connectable

PC Series

Host Link Unit /

Communication Board

CPU

CPUs Connectable with

Host Link Units or Expansion

Communication Board

Connectable

to

CS1 series

CS1W-SCB41-E

CS1G-CPU42/43/44/45-EV1
CS1H-CPU63/64/65/66/67-EV1

CS1G
CS1H

3G2A6-LK202-EV1

C1000H-CPU01-EV1
C2000H-CPU01-EV1

C1000H
C2000H

C200H-LK202-V1

C200HS-CPU01/03/21/23/31/33-E
C200HS-CPU01/21-EC
C200HE-CPU11/32/42-E
C200HE-CPU11/32/42-ZE
C200HG-CPU33/43/53/63-E
C200HG-CPU33/43/53/63-ZE
C200HX-CPU34/44/54/64-E
C200HX-CPU34/44/54/64/65/85-ZE

C200HS
C200HE
C200HE-ZE
C200HG
C200HG-ZE
C200HX
C200HX-ZE

C200HE-CPU32/42-E
C200HE-CPU32/42-ZE

C200HE
C200HE-ZE

C200HW-COM03/06-EV1

C200HG-CPU33/43/53/63-E
C200HG-CPU33/43/53/63-ZE

C200HG
C200HG-ZE

C series

C200HX-CPU34/44/54/64-E
C200HX-CPU34/44/54/64/65/85-ZE

C200HX
C200HX-ZE

3G2A5-LK201-EV1

C1000H-CPU01-EV1
C2000H-CPU01-EV1

C1000H
C2000H

C500-LK203

C1000H-CPU01-EV1
C2000H-CPU01-EV1

C1000H
C2000H

CPM1-10/20/30CDR-

j

+CPM1-CIF11

CPM1

CPM1A-10/20/30/40CD

j-j

+CPM1-CIF11

CPM1

CPM2A-30/40/60CD

j-j

+CPM1-CIF11

(Peripheral port connection)

CPM2A

CPM2C-10/20

jjjjjj-j

(*1)

CPM2C

CQM1H-SCB41

CQM1H-CPU51/61

CQM1H

CV

i

CV500-CPU01-EV1

CV500-CPU01-EV1

CV500

CV series

(*2)

CV500-LK201

CV1000-CPU01-EV1

CV1000-CPU01-EV1

CV1000

( 2)

CV2000-CPU01-EV1

CV2000-CPU01-EV1

CV2000

CVM1 se-
ries

(*2)

CV500-LK201

CVM1-CPU01-EV2
CVM1-CPU11-EV2
CVM1-CPU21-EV2

CVM1-CPU01-EV2
CVM1-CPU11-EV2
CVM1-CPU21-EV2

CVM1

SRM1

SRM1-C02-V1+CPM1-CIF11

SRM1

*1: Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11

RS-422A Adapter to connect.

*2: CPUs of CVM1/CV-series PCs without the suffix -EV

j cannot be connected.

The host link method cannot be used when an NT31/NT31C is connected using
RS-485. To use the host link method, connect by RS-422A.

Advertising