Specifications

The general specifications and communications specifications of the convertor unit are shown below.

General Specifications

Item

Specification

Dimensions

30 (W)

114 (H) 100.2 (D) mm: with the RS-422A terminal block cover closed

30 (W)

114 (H) 119.5 (D) mm: with the RS-422A terminal block cover open

Weight

200 g max.

Operating ambient temperature

0 to 55

_C

Operating ambient humidity

10% to 90% (with no condensation)

Rated power supply voltage

+5 V

" 10% (using pin No. 6 of the RS-232C connector)

Rated power supply current

150 mA max.

Rush current

0.8 A max.

Insulation resistance

20 M

Ω or higher, measured between all RS-422A terminal signal lines collectively

and functional ground terminal with a 500 VDC megger

Dielectric strength

1500 VAC for 1 minute between all RS-422A terminal signal lines collectively and
functional ground terminal

Leakage current: 10 mA max.

Operating environment

No corrosive gases

Storage ambient temperature

−20 to +75_C

Vibration resistance

Conforms to JIS C0911 60 minutes in each of X, Y, and Z directions

Shock resistance

Conforms to JIS C0912 47m/s

2

, 3 times in each of X, Y, and Z directions

Communications Specifications

RS-232C Interface

Item

Specification

Communications speed

Max. 115.2k bps

Transmission distance

Max. 2 m

Connector

9-pin D-SUB connector (female)

RS-422A/485 Interface

Item

Specification

Communications speed

Max. 115.2k bps (depends on the RS-232C communications speed)

Transmission distance

Max. 500 m

Connector

8-terminal detachable terminal block, M3.0