2 agency approvals – Orion 2xx User Manual

Page 25

Advertising
background image

22

46-649 Jupiter Magnetostrictive Transmitter - F

OUNDATION

fieldbus™

5.2

Agency Approvals

FM & CSA

2X1-XXXXXXX-XXX

Intrinsically Safe

Class

I, Div. 1:

2X2-XXXXXXX-XXX

Groups A, B, C, & D

2X3-XXXXXXX-XXX

Class

II, Div. 1:

2X4-XXXXXXX-XXX

Groups E, F, & G
Class

III, IP66 TYPE 4X, T4

FISCO

2XX-XXXXXXX-XXX

Explosion Proof

Class

I, Div. 1

Groups B, C, & D
Class

II, Div. 1

Groups E, F, & G
Class

III, IP66 Type 4X T5 at 80° C

2XX-XXXXXXX-XXX

Non-Incendive

Class

I, Div. 2

Groups A, B, C, & D
Class

II, Div. 2

Groups E, F, & G

Class

III, IP66 Type 4X T5 at 80° C

ATEX

2XA-XXXXXXX-XXX

Flame Proof

II 1/2 G EExd IIC T6

2XB-XXXXXXX-XXX
2XC-XXXXXXX-XXX
2XD-XXXXXXX-XXX

2XE-XXXXXXX-XXX

Intrinsically Safe

II 1 G EEx ia IIC T4

2XF-XXXXXXX-XXX

FISCO

2XG-XXXXXXX-XXX
2XH-XXXXXXX-XXX

AGENCY

MODEL

PROTECTION METHOD

AREA CLASSIFICATION

M20 conduit connections not CSA approved explosion proof

FM approval Class II, Div. 2 Groups F & G only

Materials marked as category 1 equipment and used in hazardous areas requiring this category, shall be installed in such a way that, even in
the event of rare incidents, the aluminum enclosure cannot be an ignition source due to impact or friction

5.2.1 Agency Specifications –

Explosion Proof Installation

Factory Sealed: This product has been approved by Factory
Mutual Research (FM) and Canadian Standards Association
(CSA) as a Factory Sealed device.

NOTE: Factory Sealed: No Explosion Proof conduit fitting (EY seal) is

required within 18" of the transmitter. However, an Explosion
Proof conduit fitting (EY seal) is required between the haz-
ardous and safe areas.

Caution: Grounding (+) will cause faulty operation, but will not

cause permanent damage.

5.2.2 Agency specifications ATEX Intrinsically safe

Entity parameters Fieldbus Fisco:
Ui = 17.5V Ii=380mA Pi = 5.32W Ci = 0.705 nF Li = 3µH