5 model numbers, 1 enhanced jupiter magnetostrictive transmitter – Orion 2xx User Manual

Page 31

Advertising
background image

28

46-649 Jupiter Magnetostrictive Transmitter - F

OUNDATION

fieldbus™

5.5

Model Numbers

5.5.1 Enhanced Jupiter Magnetostrictive Transmitter

2

Enhanced Jupiter Magnetostrictive

TRANSMITTER TYPE

See page 29

MOUNTING CONNECTION

See page 29

FLOAT

See page 30

INSERTION LENGTH

4

LCD display, 4–20 mA & HART, SIL 1

5

LCD display & F

OUNDATION

Fieldbus

6

LCD display, 4–20 mA & HART, SIL 2

7

Interface transmitter, 4–20 mA & HART, with LCD display, 2 floats

8

Interface transmitter, F

OUNDATION

Fieldbus, with LCD display, 2 floats

OUTPUT

D

Direct Insertion, Construction codes 1 through 7

E

Top Mount, Construction code 1

F

Top Mount Offset, Construction code 1

G

Top Mount Offset, high-temperature bend, Construction code 7

H

Bottom Mount Offset, Construction code 1

J

Bottom Mount Offset, high-temperature bend, Construction code 7

CONFIGURATION (see drawings on page 34)

E

Inches

M

Centimeters

PROBE UNITS

1

316/316L SS (standard), +250° F (+120° C) Maximum (Direct Insertion +200° F (+95°))

7

316/316L SS (high temperature) +500° F (+260° C) Maximum

2

Hastelloy

®

C, +200° F (+95° C) Maximum

3

Monel

®

, +200° F (+95° C) Maximum

5

Electropolished 316/316L SS, +200° F (+95° C) Maximum

6

Sanitary 316/316L SS, +200° F (+95° C) Maximum

MATERIALS OF CONSTRUCTION

1

Cast Aluminum, Integral Mount with

3

4

" NPT Conduit Entry

FM, EP, NI & IS

2

Cast Aluminum, Integral Mount with M20 Conduit Entry

FM, EP, NI & IS

3

316 SS, Integral Mount with

3

4

" NPT Conduit Entry

FM, EP, NI & IS

4

316 SS, Integral Mount with M20 Conduit Entry

FM, EP, NI & IS

A

Cast aluminum, Integral Mount with

3

4

" NPT conduit entry

ATEX, EEx d

B

Cast aluminum, Integral Mount with M20 conduit entry

ATEX, EEx d

C

316 SS, Integral Mount with

3

4

" NPT conduit entry

ATEX, EEx d

D

316 SS, Integral Mount with M20 conduit entry

ATEX, EEx d

E

Cast aluminum, Integral Mount with

3

4

" NPT conduit entry

ATEX, EEx ia

F

Cast aluminum, Integral Mount with M20 conduit entry

ATEX, EEx ia

G

316 SS, Integral Mount with

3

4

" NPT conduit entry

ATEX, EEx ia

H

316 SS, Integral Mount with M20 conduit entry

ATEX, EEx ia

HOUSING MATERIAL, MOUNTING AND CONDUIT ENTRY

2

The bottom 3 inches of SIL 2
direct insertion probes are
inactive. The inactive area is
used to detect float failure.

Consult factory for process
temperatures of 500°–850° F
(260°–455° C)

Direct insertion model only.
Consult factory for process
temperatures above +200° F
(+95° C)

Advertising