3 - 10
3.3.5
High-Voltage Power Supply Board
(1) Dismount upper cover assy. (See Section 3.3.4.)
(2) Remove three screws
1
and draw out high-voltage power supply board
2
.
(3) Disconnect all the cables
3
from high-voltage power supply board
2
and dismount high-
voltage power supply board
2
.
Caution:
Note the following when assembling the high-voltage power supply board:
• Mount the high-voltage power supply board with top cover assy removed or
open.
• Take care that cable
3
will not interfere with the paper sensor exit when it is
connected.
Paper sensor exit
3
2
1