4

Heat assy error

• Turn the power supply off, then on again.

• Does the Halogen lamp of the heat assy go on?

• No

Is the Halogen lamp or thermostat disconnected?

• Yes Replace the heat assy, Halogen lamp, or thermostat.

• No

Replace the power supply unit.

• Yes

Are the CN2 connectors of the power supply unit and main control board connected

correctly?

• No

Connect the CN2 connectors correctly.

• Yes

Replace the main control board.