Castile Pellet Insert

5

Venting Systems

NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.

Figure 15.1

Fire Risk.

Inspection of Chimney:

• Masonry chimney must be in good condition.

• Meets minimum standard of NFPA 211

• Factory-built chimney must be a minimum 6 inch

(152mm) UL103 HT.

WARNING

CAUTION

Never draw outside combustion air from:
• Wall, fl oor or ceiling cavity
• Enclosed space such as an attic or garage

NOTE:
Illustrations refl ect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design

preference.

A. Full Reline With Outside Air - Horizontal

Outside Air through Rear
Wall (Horizontal)

NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as fiberglass, mineral
wool or ceramic.

Do not use high temperature
caulking materials to seal any
edge to prevent furture service-
ability.