Page 4

250-7251G

August 20, 2009

R

Castile Pellet Insert

1

Listing and Code Approvals

A. Appliance Certifi cation

C. Glass Specifi cations

E. BTU & Effi ciency Specifi cations

This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.

NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-95, ULC S628-93, ULC/ORD-C-1482-
M1990 and (UM) 84-HUD

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

*BTU output will vary, depending on the brand of fuel you
use in your appliance. Consult your Quadra-Fire dealer
for best results.

NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifi cations and/or price without notice.

MODEL:

Castile Pellet Insert

LABORATORY:

OMNI Test Laboratories, Inc

REPORT NO.

061-S-42-2

TYPE:

Solid Fuel Room Heater/Pellet Fuel
Burning Type Insert

STANDARD:

ASTM E1509-95, ULC S628-93 and
ULC/ORD-C1482-M1990 Room
Heater Pellet Fuel Burning Type and
(UM) 84-HUD, Mobile Home Approved

Colorado:

Approved 11-15-02

Particulate Emis-
sions Rating:

0.7 grams/hr

*BTU Output:

8,000 - 30,000 / hr

Heating Capacity:

up to 1,500 sq. ft. depending
on climate zone

Hopper Capacity:

45 lbs

Fuel:

Wood Pellets or Shelled Corn

Shipping Weight:

260 lbs

WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency
listing will be voided by the above actions.

DO NOT:

• Install or operate damaged appliance

• Modify appliance

• Install other than as instructed by Hearth & Home

Technologies

• Operate the appliance without fully assembling all

components

• Overfi re

• Install any component not approved by Hearth &

Home Technologies

• Install parts or components not Listed or approved.

Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.

For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.

Quadra-Fire is a registered trademark
of Hearth & Home Technologies.

This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is used.

The structural integrity of the mobile home fl oor, ceiling, and
walls must be maintained.

The appliance must be properly grounded to the frame of
the mobile home and use only Listed pellet vent Class “L”
or “PL” connector pipe.

A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation. You must order the Outside Air Kit sepa-
rately.

B. Mobile Home Approved

Note: The appliance is also approved for installation
into a shop.