Reference materials – Quadra-Fire CASTINS-CSB User Manual

Page 39

Advertising
background image

R

August 20, 2009

250-7251G

Page 39

Castile Pellet Insert

11

Reference Materials

7. Heat Exchangers

The heat exchangers transfer heat from the exhaust system
into convection air. There are 2 clean out rods located under
the heat exchangers.

8. Heat Output Switch

The heat output switch is located on the lower right side of
fi rebox, behind the right face above the reset button. The
function of the heat output switch is to regulate the burn rates;
low, medium and high settings.

9.

Igniter

The igniter is mounted on the base of the fi repot. Combustion
air travels over the red hot igniter creating super heated air
that ignites the pellets.

10. Junction Box And Wiring Harness

The junction box is located behind right cast side of the
appliance. The junction box and wiring harness are replaced
as one component.

11. Power Supply

The power outlet is located behind the right cast side of the
appliance behind the thermostat block on the junction box.
Check the wall receptacle for 120 volt, 60 Hz (standard
current). Make sure the outlet is grounded and has the correct
polarity. A good surge protector is recommended. When
operating with a generator you need at least 600 watts of
power, or with an inverter at least 800 watts of power available
for the appliance during the start cycle.

12. Red Call Light

The red call light is located behind the fuse behind the right
cast side. The function of the red call light is to indicate that
the thermostat is calling for heat.

13. Reset Button

The reset button is located on the lower right side of fi rebox
behind right face and below the heat output control switch. The
function of the switch is to momentarily open the thermostat
circuit, which restarts the system.

14. Thermocouple

The thermocouple is located on top of the fi repot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control box
indicating the preset temperatures of the green and red lights
have been obtained.

15. Thermostat

The appliance is designed to run on a 12 volt AC thermostat.
The heat anticipator, if present, should be set on the lowest
setting available.

When describing the location of a component
part it is always AS YOU FACE THE FRONT
OF THE APPLIANCE.

2. Convection Blower

The convection blower is mounted at the bottom rear of the
appliance. There are 2 impellers, one on each side of the
motor. The convection blower pushes heated air through the
heat exchange system into the room.

3. Exhaust Blower

The exhaust blower is mounted on the right side of the
appliance behind the right cast side. The exhaust blower is
designed to pull the exhaust from the appliance and push it
out through the venting system.

4. Feed System

The feed system is located on the right side and can be
removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger). The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the fi repot.

5. Firepot

The fi repot is made of high quality ductile iron and has a
cleaning pull-out rod. The fl oor of the fi repot opens for
cleaning when you pull out the rod. Be sure that the fl oor
returns to a completely closed position or your appliance will
not operate properly.

6. Fuse

The fuse is located on the right side behind the control box.
The fuse will blow should a short occur and shut off power
to the appliance.

NOTE:

Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the control
box you must fi rst unplug the appliance.

1. Control Box

a. The control box is located on lower right side of

appliance, behind cast side on top of the junction
box.

b. There is a light located inside of the control box. The

internal light will turn green when the appliance has
reached a temperature of 200

ο

F (93°C) in the fi repot.

and will turn red when it reaches 600

o

F (315°C).

c. There is also an internal blue light located in the upper

left corner of the control box. When you plug in the
appliance the blue light will automatically start blinking
6 blinks every 10 seconds for 60 seconds and then will
stop.