Warning – Quadra-Fire CASTINS-CSB User Manual

Page 9

Advertising
background image

R

August 20, 2009

250-7251G

Page 9

Castile Pellet Insert

A

C

B

B

C

E

D

Fire Risk.

Comply with all minimum clearances
to combustibles as specifi ed.

WARNING

Failure to comply may cause house
fi re.

NOTE:

Illustrations refl ect typical installations

and are FOR DESIGN PURPOSES
ONLY.

Illustrations/diagrams are not drawn to

scale.

Actual installation may vary due to

individual design preference.

B. Clearance To Combustibles, UL and ULC

Inches

Millimeters

A

Top of Hopper

Top or Rear Vent

0

0

B

Side of Outside Skin

Top or Rear Vent

0

0

C

Back of Hopper

Top Vent

2.5

64

Rear Vent

0

0

D

Vent Pipe to Combustible

Top or Rear Vent

3.0

76

E

Front Panel Edge

Top or Rear Vent

0

0

INSTALLED AS A BUILT-IN UNIT

Shown Optional Outside Air

Figure 9.1

Figure 9.2

AS A BUILT-IN

0” (0mm) Clearance To Exposed Section And Face Trim

12 in

(305mm)

6 in

(153mm)

Outside

Air

Advertising
This manual is related to the following products: