NOTE: Check clearances carefully for this type of instal-
lation to ensure adequate room for outside air venting.

Check building codes prior to installation.
• Installation MUST comply with local, regional, state and

national codes and regulations.

• Consult local building, fi re offi cials or authorities having

jurisdiction about restrictions, installation inspection, and
permits.

CAUTION

NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482-M1990.

B. Full Reline With Outside Air - Vertical

Figure 16.1

Outside Air

Termination

at

Chimney Top

(Vertical)

305mm min.
below

305mm min.
above

NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insula-
tion such as fiberglass, mineral
wool or ceramic.

Do not use high temperature caulk-
ing materials to seal any edge to
prevent furture serviceability.

NOTE: In Canada this fi replace insert must be installed
with a continous chimney liner a 6 inch (152mm) in diam-
eter extending from the fi replace insert to the top of the
chimney. The chimney liner must conform to the Class
3 requirments of CAN/ULC-S635, Standard for Lining
Systems for Extising Masonry or Factory-Built Chimneys
and Vents, or CAN/ULC-S640, Standard for Lining Sys-
tems for New Masonry Chimneys.