Inverting the word clock, Word clock errors, Inverting the word clock word clock errors – Tascam DS-M7.1 User Manual

Page 15: 3 – connections

Advertising
background image

3 – Connections

TASCAM DS-M7.1

15

Console

and

MasterRec

(mastering

recorder).

The second and third lines of the screen will
be automatically filled in depending on both
the source and the settings made elsewhere in
the system as described in “Routing and
patching” on page 19. P
ossible values are:

NOTE

High-speed connections cannot be made using the TAS-
CAM DM-24 digital mixing console. They may not be
supported by other equipment, and you should check
carefully in the documentation of all the components of
your system to ensure that this is a valid option.

Only the analog and AES/EBU connections and option
cards support 96k operation on the DS-M7.1.

Inverting the word clock

In some cases, the polarity of the word clock received
at the

WORD IN

connector may be inverted relative

to what the DS-M7.1 expects (since no industry stan-
dard has been universally adopted). In this case, you
may need to invert the polarity of the clock so that it
syncs accurately with the other devices in the setup.

1

Press the

SYSTEM

key, and use the cursor

keys until a screen similar to the following
appears:

2

Switch the

WordIN

parameter between

Normal

and

Reverse

.

Word clock errors

In the event of a word clock error, the display back-
light flashes, the output is muted, and the screen

shows

[SYSTEM] *n

where

n

is a number rep-

resenting the error, as explained below:

Source

Possible sources

Possible sampling

frequencies (kHz)

Word In

Word In only

44.1, 48, 88.2, 96

Console

TDIF (internal)

44.1, 48

EX TDIF (slot)

44.1, 48

EX AES/EBU (slot)

44.1, 48 (normal),
88.2, 96 (high)

EX ADAT (slot)

44.1, 48

Master Rec

TDIF (internal)

44.1, 48

AES/EBU (internal)

44.1, 48 (normal),
88.2, 96 (high)

ADAT (internal)

44.1, 48

[ S Y S T E M ]

< >

L F E G a i n

+ 1 0 d B

S o l o

E x l u s i v e

W o r d I N

N o r m a l

Error
number

Meaning

Appropriate action to take

0

No master clock.

Check the connections between the DS-M7.1 and the clock master, and check the set-
tings on the clock master to ensure that it is actually outputting a word sync signal.

1

Master clock out of range (44.1 kHz)

Check the settings of the clock master, and make sure that it is within ±6% of the
stated nominal frequency

2

Master clock out of range (48 kHz)

3

Master clock out of range (88.2 kHz)

4

Master clock out of range (96 kHz)

Advertising