Operating the equipment remotely, Introduction, Remote ethernet (snmp) operation – TANDBERG TT1282 User Manual

Page 16: Basic unit set-up, Set the transport stream input, 1 set the transport stream input

Advertising
background image

TT128x High Definition Professional Receiver/Decoder

16

5

Operating the Equipment Remotely

5.1

Introduction

When an external control system is used the Receiver may be

configured, controlled and monitored remotely.

5.2

Remote Ethernet (SNMP) Operation

If the Receiver is to be controlled via its Ethernet interface the unit's IP
address and associated parameters must be set in the relevant menus.

Firstly, the unit’s IP address should be set (Menu 7.1.3). Then the unit

subnet mask should be set (Menu 7.1.3.1) and if the controlling device

is on a separate network accessed through a gateway router then the

gateway IP address should be set (Menu 7.1.3.2). Finally the operating

mode should be set to “NETWORK (SNMP)” (Menu 7.1). The SNMP MIB

for the IRD is available from TANDBERG Television.

6

Basic Unit Set-up

6.1

Set the Transport Stream Input

Navigate to the Input Menu (Menu 2.1/2.2) and select the transport

stream input source required. This menu always has options ASI or

SMPTE 310. Dependent upon what additional input option cards have

been fitted, G.703, QPSK or IP may also be selected.

ASI/SSI Input

No other parameters need be set.

G.703 Input

>

Set the Reed-Solomon (Menu 2.3.2)

>

Set the Interleaver (Menu 2.3.3)