TASCAM SS-R1/SS-CDR1 RS-232C Protocol Specification


11

TEAC

Corporation

PITCH CONTROL DATA PRESET

Specifies the playback pitch of the controlled device in % units.
The adjustable range is ±16.0%.
This can be set independently of the step that is specified by the SS-R1/SS-CDR1's PITCH STEP?
setting.
A return command is returned only if Sense [FF] is specified..
If Sense [FF] is specified, the data is two bytes.
The pitch control mode setting is made by the command "PITCH CONTROL SELECT [35]."
Command 25
Machine ID

0

Data

4 bytes or 2 bytes

Data

1

Data

2

Data

3

Data

4

Description Remarks

0

1

Positive

value

Negative value

N2 N3 N1

Preset %

N1:Tens digit, N2: Ones digit, N3:First decimal
place

Example) 2311:-12.3%

F

F

Sense

Requests that the currently preset pitch be
returned.

If data other than the above or data outside the specified operating range is received, the
SS-R1/SS-CDR1 will transmit ILLEGAL [F2].

Return

PITCH DATA RETURN [A5]


AUTO TRACK TIME PRESET

Specifies the Auto Track Time setting of the controlled device.
The range that can be specified is 1 to 10 minutes.
A return command is returned only if Sense [FF] is specified.
The Auto Track Mode setting is made by the command "AUTO TRACK SELECT [31]."
Command 26
Machine ID

0

Data 2

bytes

Data 1

Data 2

Description

Remarks

N1 N2

Minutes N1: Tens digit of minutes, N2: Ones digit of minutes

F

F

Sense

Requests that the currently preset time be returned.

If data outside the specified range is received, the controlled device will return ILLEGAL[F2].

Return

AUTO TRACK TIME RETURN [A6]

Advertising