TASCAM SS-R1/SS-CDR1 RS-232C Protocol Specification


32

TEAC

Corporation


ERROR SENSE REQUEST

This is transmitted when the controlled device is in an error condition.
If this command is transmitted from the controlled device, the external controller device should
transmit the command "ERROR SENSE [78]" to determine the content of the error.
Command F0
Machine ID

0

Data none
Request/Preset none


CAUTION SENSE REQUEST

This is transmitted when the controlled device is in a caution condition.
If this command is transmitted from the controlled device, the external controller device should
transmit the command "CAUTION SENSE [79]" to determine the content of the warning.
Command F1
Machine ID

0

Data none
Request/Preset none


ILLEGAL STATUS

This command is returned when an invalid command or data has been sent to the controlled device.
If this command is transmitted from the controlled device, the external controller device should
re-transmit the correct command or data in compliance with the specifications.
Command F2
Machine ID

0

Data none
Request/Preset none


POWER ON STATUS

This command indicates that the controlled device has been powered-on.
Command F4
Machine ID

0

Data none
Request/Preset none


CHANGED STATUS

This command indicates that the operation or mode of the controlled device has changed.
Command F6
Machine ID

0

Data 2

bytes

Data 1

Data 2

Description

Remarks

0 0

Changed

Mechanical

Status

The status of the mechanism has changed

0 3

Changed

Track/EOM

Status

The track number has changed. The EOM
display/non-display state has changed.

Request/Preset none