JUNCTION BOX

1. Loosen the screw securing the junction

box and remove the cover.

2. Remove the knockouts (if necessary) or

use the provided cable clamp.

3. Pull out the three wires marked T1, T2,

and TG. (red, red, and green)

4. Remove the wire connector and separate

the wires marked T1 & T2.

5. Connect the (red) T1 wire from the unit

to the white (neutral) wire from the wall

thermostat box by using a wire connector.

(not supplied)

6. Connect the other end of the white

(neutral) wire from the thermostat wall

box to the red wire from the wall

thermostat.
7. Connect the (red) T2 wire from the unit to

the black wire from the thermostat wall

box by using a wire connector.

(not supplied)
8. Connect the other end of the black wire

from the thermostat wall box to the black

wire from the wall thermostat.

9. Connect the green (ground) TG wire from

the unit to the green (ground) wire from

the thermostat wall box by using a wire

connector. (not supplied)

Section 7: Wall Mounted Thermostat Wiring For 120/240 Volt

ATTENTION

• Install main power connection with

appropriate voltage as per Section C

or Section D.

• Install a 2 conductor wire with ground

(3 wires total) from the thermostat wall

box to the junction box on the unit.

• Wiring of the thermostat must be

completed prior to the mounting of

the unit.

• The following installation instructions are

for a single pole thermostat.

Junction Box Locator: Figure 10

10. Connect the other end of the green

(ground) wire from the thermostat wall

box to the back plate of the wall mounted

thermostat with a ground screw.

11. Ensure that all connections are tight.
12. Insert all the wiring of the wall mounted

thermostat into the wall box.

13. Insert all the wiring back into the unit and

secure with a cable clamp.