Framing Specifications: Figure 1

This fireplace is a zero clearance design. No

combustibles can be placed on the top

surface of the fireplace. Combustibles may

be installed to the edge of the unit.

For 120 volt installations use two conductor,

non-metallic sheath cable with ground wire

(3 wires total) for the incoming power supply

on fireplace inserts. Use the appropriate wire

to meet local and national electrical codes for

rated power consumption.

For 208/240 volt installations use three

conductor, non-metallic sheath cable with

ground wire (4 wires total) for the incoming

power supply on fireplace inserts. Use the

appropriate wire to meet local and national

electrical codes for rated power consumption.

MODEL

A

B

C

D

E

F

G

H

I

J

K

L

M

33EB304AAS

15.0”

33.0”

29”

28.5”

23.0”

32.8”

29.6”

18.25”

23.6”

14.3”

48.0”

28.0”

28.0”

33EB364GRS 16.0”

39.0”

33”

32.7”

27.2”

38.7”

36.0”

22.0”

27.6”

15.3”

55.0”

34.0”

34.0”

D

E

F

G

H

I

J

L

K

M

Four mounting flanges on the sides of the unit

are provided to facilitate installation.

Insulation and vapor barrier should be placed

a minimum of 2 inches from the unit.

Two conductor, non-metallic sheath cable with

ground wire (3 wires total) is recommended

for installation of a wall mounted thermostat

for use on fireplace inserts.

Recommended Wire and

Fusing Requirements

Use appropriate wire to meet local and

national electrical codes for rated power con-

sumption. All wire gauges should be

12 gauge with a dedicated 15 amp breaker.

Section 2: Recommended Power Supply Wire Specifications

Section 1: Framing

E-3