Important – Twin-Star International 33EB304GRS User Manual

Page 8

Advertising
background image

JUNCTION BOX

1. Locate the voltage selector switch inside

the exhaust panel on the top left hand

corner of the unit. (see figure 2 on page 3)
2. Confirm the switch is set to 240 volt

configuration (230 volt is printed

on switch).
3. Loosen the screw securing the junction

box cover and remove the cover.
4. Remove the knockouts (if necessary) or

use a cable clamp (not provided).

5. Pull out the four wires marked L1, L2,

N, and G.
6. Connect the black L1 wire from the unit to

the black L1 from the power supply.

7. Connect the red L2 wire from the unit to

the red L2 from the power supply.

8. Connect the white N wire from the unit to

the white N wire from the power supply.
9. Connect the green ground wire from the

unit to the ground from the power supply.
10. Ensure that all connections are tight.
11. Insert all the wiring back into the unit and

secure with a cable clamp.

Section 6: 240 Volt Installation Instructions

Important

• The unit is factory configured for 120 volt

operation. You must set the voltage

selection switch to 240 volts (230 volt is

printed on the switch.

• Use 3 conductor wire with ground (4 wires

total) from the power supply (breaker

panel) to the junction box on the unit.

• All wiring must be completed prior to

installing the unit.

• Ensure that the voltage selector switch is

in the proper position for the required

supply voltage prior to connecting the unit

to the power supply.

Junction Box Locator: Figure 8

E-8

Advertising
This manual is related to the following products: