A setting of clothes weight, A weight only function – Tanita Body Composition Analyzer BC-418MA User Manual

Page 10

Advertising
background image

GB

GB

a Setting of Clothes Weight

1. After turning on the unit, press the [

] key.

After a momentary display check, “0.0” will appear
on the LCD. If measuring units need to be changed,
do so at this time by pressing the [

]key.

An arrow on the LCD will follow the selection of
weighing units.

2. Weight Measurement.

Step on the weighing platform. Weight will be
displayed on the LCD.

3. When measuring is complete, press the [

]

key to turn off the power.

ƽ

No printer is available when measuring
weight only.
If body composition analysis is desired, turn
the unit off and then on, using the [

]

key.

Important Note: There is no automatic weight lock

function.

1. Press the [

] key.

The arrow next to P T t will flash.

2. Enter the clothes weight.

Example: If the clothes weight is 2.0 kg, press [2], [.]

and then [0].

* When you want to correct an entry, press the [

]

key and enter the data again.

3. Finalizing the setting

Press the [

] key to finalize the clothes weight.

The finalized clothes weight is displayed with a
minus, an arrow next to P T t lights up, and it
becomes possible to measure your weight.

P T

P T

a Weight Only Function

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

P T

ATHLETIC

STEP ON

~

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

P T

9. Taking Measurement.

Step on the weighing platform in bare feet. Make sure heels
are placed on the posterior electrodes, and the front part of
the feet are in contact with the anterior electrodes.

10.Measure the Impedance.

When the grips are grasped with both hands,
will appear at the bottom of the display and the
impedance measurement will begin.

The

marks will disappear one by one during the

measurement; after five full cycles, the measurement will be complete.

ƽ

Grab the grips (two locations) only after the body
weight figure on the display has stabilized.

Do not step off the Weighting Platform until
the “

” symbols disappear completely.

In cases when measurements of the body fat ratio
or the quantity of fat are abnormally small or the
error message (E01) is shown on the display, the
probable reason is that the soles of the feet and the
electrodes are not in full contact. Make sure you
step on the Weighing Platform so there is contact
between the electrodes and the soles of your feet.
If the problem is not solved this way, it is possible
that the soles of the feet have calluses and the
resistance is too great. Therefore, place about 0.5
ml of water on each of the four electrodes where
the feet touch before measurement.

11.Measurement Is Completed.

Once the body weight and impedance measurements have
been completed, the overall body fat percentage will be
shown at the bottom of the display and a buzzer will sound.
If the printer is ON, the measurement results will be printed out.
* With regard to the measurement result, please refer to P. 22.

If the printer is OFF, the measurement results (predicted
muscle mass, fat mass, and body fat percentage) for each
body part can be displayed using the ten-key pad.
Select the number of the desired body part on the ten-key pad.
[4]:

Left arm

[6]:

Right ar

[0]:

Left leg

[ . ]:

Right leg

[5] and [2]: Trunk
* See page 13 for details on printer settings.
Step off the Weighing Platform.

12.When You Continue to Measure.

After printing is completed, go back to step 3.
Measure by entering the data in the same procedure.

13.Finish Measurement.

Press the [

] key and turn off the power.

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

ATHLETIC

STEP ON

FEMALE

MALE

kg

cm / ft.in

STABILIZED

AGE

% FAT

P T

R

R

L

L

Right leg

Left leg

Right arm

Left arm

Trunk

Advertising