Termination clearances – Temco Tool DV1400N/P User Manual

Page 11

Advertising
background image

11

Temco DV1000/1200/1400 Series

76657

NOTE: Use only venting systems and components
as certified with the appliance. Use of uncertified vent
systems or components will void the warranty and may
compromise the operation of the fireplace, its systems,
and components as certified with the appliance.

2" (51mm)

1" (25mm)

1"

(25mm)

T181

vent clearances

12/3/03 djt

Top of Vent

Combustibles

NOT Allowed in

Shaded Area

4” Dia. Flue

7” Dia. Intake

Vent

T181

Fig. 11 Vent clearances.

0

5'

46"

(1168mm)

33¹⁄₂"

(851mm)

10'

15'

25'

30'

32'

0

3'

5'

10'

15'

T180

DV vent graph

12/3/03 djt

*

A vent guard should be

used whenever the termina-

tion is lower than the speci-

fied minimum or as per local

codes

* Min. Refer to Chart on Page 6

T180

Fig. 12 Venting graph.

Fig. 10 Termination clearances.

Outside Corner

Inside Corner

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

G =

Combustible

6" (152 mm)

Noncombustible

2" (51 mm)

F =

Combustible

6" (152 mm)

Noncombustible

2" (51 mm)

G

Balcony -

with no side wall

M =
Combustible &
Noncombustible
12" (305 mm)

M

Balcony -

with perpendicular side wall

M = 24" (610 mm)
P = 20” (508 mm)

M

F

Alcove Applications*

C

D

C

E

V

V

Combustible &

Noncombustible

V

V

V

E

= Min. 6” (152 mm) for

non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls

O

= 8’ (2.4 m) Min.

O

P

584-15

No.

of Caps

D

Min.

C

Max.

1

3’ (914 mm) 2 x D

Actual

2

6’ (1.8 m)

1 x D

Actual

3

9’ (2.7 m)

2/3 x D

Actual

4

12’ (3.7 m)

1/2 x D

Actual

D

Min.

= # of Termination caps x 3

C

Max.

= (2 / # termination caps) x D

Actual

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All
mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All
gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.