Managing heat output, Fan operation, Flame characteristics – Temco Tool DV1400N/P User Manual

Page 27

Advertising
background image

27

Temco DV1000/1200/1400 Series

76657

FP387

SIT Valve and pilot

HI

LO

OFF

ON

OFF

PI

LO

T

O

FF

E

A

PILOT

THTP

TP

TH

Pilot Screw

Wall Switch

(not supplied)

Thermopile

Pilot

Ignitor

To Piezo

Thermocouple

Manifold Pressure

Supply Pressure

IN

OUT

FP387

Fig. 37 Pilot and valve wiring.

Recommended Maximum Lead Length

(Double Wire)

When Using Wall Switch or Thermostat

Wire Size

Max. Length

14 ga.

50’ (15.2 m)

16 ga.

32’ (9.8 m)

18 ga.

20’ (6 m)

20 ga.

15’ (4.6 m)

22 ga.

10’ (3 m)

NOTE: All Models are supplied with 15’ (4.6 m) of
double wire for use with a wall switch.

CAUTION: Do not wire 120V power to mil-
livolt switches or thermostats.

Managing Heat Output

The heat output from the appliance may be controlled
by adjusting the main gas valve. Reference lighting
instructions on Page 28 and chart on Page 34 showing
inputs at all the settings.
The main gas valve may be adjusted anywhere be-
tween high and low to give the desired combination of
flame aesthetics and heat output.

HI

LO

T155

PS24

hi/lo knob

11/10/03 djt

Turn knob clockwise

to increase flame

Turn knob

counterclockwise

to decrease flame

Fig. 38 Flame adjustment knob.

Fan Operation

The fan operates automatically - turn the knob on the
speed control to adjust to the desired speed. The fan
will turn on as the fireplace comes up to operating tem-
perature. After the unit has been turned off and the unit
cooled to below a useful heat output range the fan will
shut off automatically.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figure
39.
If the flame patterns appear abnormal, contact a quali-
fied service provider for service and adjustment.
Pilot Burner Adjustment
1. Adjust pilot screw to provide proper sized flame.
2. Leak test.

F584-703

Honeywell

& PSE

pilot flames

3/8” - 1/2”

(10 - 13 mm)

F584-703

Fig. 39 Correct flame appearance.

Advertising