Thermostatic fan kit - optional, Electrical services, Speed control switch – Temco Tool DV1400N/P User Manual

Page 26: Millivolt system, Burner on/off control

Advertising
background image

26

Temco DV1000/1200/1400 Series

76657

Thermostatic Fan Kit - Optional

(Part # GDVTFK)
For installation of the optional fan, please refer to the
instructions included in the fan kit.

Electrical Services

Optional fan kits are equipped with a 120V, 60Hz
blower, less than 12 amps.
If electrical supply 120V is being roughed in to provide
for future installation of an optional blower kit, an ap-
proved surface mount, steel electrical box, cover and
strain relief bushing must be installed in the fireplace
(supplied by others).
NOTE: All electric connections are to be made in ac-
cordance with CSA Standard C22.1 - Canadian Electri-
cal Code part 1 or with the National Electrical Code,
ANSI/NFPA 70 (latest addition) and/or in accordance
with local codes.

TL121

DV1000/DV1200

final position logs

12/11/03 djt

TL121

Fig. 34 DV1000 and DV1200 logs in final position.

TL122

Dv logs

side view

12/11/03 djt

Back Log

Twig

Slot

Bracket

Bracket

Front Log

TL122

Fig. 35 Side view of logset. (NOTE: The side logs for the
DV1400 are not shown.)

Speed Control Switch

1. The blower combination on/off switch and electronic

speed control is supplied loose to allow mounting in
a conveniently located wall mounted electrical box.

2. Wire speed control into black (hot) side of 120V,

60Hz line as shown in blower wiring diagram.

M

White

Black

T173

blower wiring

11/14/03 djt

G

Green

120
Volt

Speed Control

Switch

Temperature
Sensor

Fan

T173

Fig. 36 Fan wiring diagram.

CAUTION: Should this fan require servic-
ing, the power supply must be discon-
nected.

Millivolt System

CAUTION: At installation and/or after any
service work or repairs glass door must be
removed before proceeding to lighting instruc-
tions.
CAUTION: At installation and/or after any
service work or repairs glass door must be
removed before proceeding to lighting instruc-
tions.

Burner On/Off Control

All models may be used with an optional wall switch
that turns the main burner on or off. Optional millivolt
thermostats (GFPMT) and remote control may be sub-
stituted for the wall switch (For installation of these op-
tions, detail instructions are provided with optional kits).
CAUTION: If the remote receiver is located in the gas
control area (under the firebox), clearance should be
below the firebox at least 2” (51 mm) to avoid high tem-
peratures (receiver should not be exposed to tempera-
tures exceeding 130°F).