34

Temco DV1000/1200/1400 Series

76657

Normal and High

Direct Vent Units - Inputs - Orifice Size - Altitude

BTU/Hr

BTU/Hr

Manifold Pressure

Orifice 0 - 2000ft. Altitude in USA

Model

Min. Input

Max. Input

@ Max.

Orifice 0-4500ft Altitude in Canada

DV1000N

12,500

18,500

3.5”w.c.

#46 DMS

DV1000P

12,500

18,500

10.0” w.c.

#56 DMS

DV1200N

13,000

20,000

3.5” w.c.

#45 DMS

DV1200P

13,000

20,000

10.0” w.c.

#55 DMS

DV1400N

15,000

22,000

3.5” w.c.

#43 DMS

DV1400P

15,000

22,000

10.0” w.c.

#54 DMS

Conversion Kits

Change Natural Change Propane

Model

to Propane

to Natural

DV1000N

B32ACLP

--

DV1000P

--

B32ACNG

DV1200N

B36ACLP

--

DV1200P

--

B32ACNG

DV1400N

B42ACLP

--

DV1400P

--

B42ACNG

Air Shutter Settings

Opening

Opening

Model

“A” (inches)

“A” (mm)

DV1000N

1/8”

3.2 mm

DV1000P

1/8”

3.2 mm

DV1200N

1/8”

3.2 mm

DV1200P

3/16”

4.7mm

DV1400N

1/8”

3.2mm

DV1400P

1/4”

6.3mm

IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.

NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.

T203

Air shutter

12/12/03 djt

Opening
“A”

T203

Fig. 40 Air shutter opening.