Communications-related parameters – Toshiba DEV002Z User Manual

Page 14

Advertising
background image

E6581295⑥

- 13 -

5. Communications-related parameters

On the network, the VF-AS1/PS1 (including the DEV002Z) serves as a slave device.
Using the parameters listed below, set the slave device on the network and its mode of
operation.

These settings can also be made by the use of configuration tools and the EDS file. The
EDS file can be downloaded from the following web site.

http://www.inverter.co.jp/product/inv/vfas1/dev/index_i.htm

Parameter

Function

Adjustment range

Default setting

f830

*

Communication option

setting 1

Assembly

Object

0: Instance 20/70
1: Instance 21/71
2: Instance 100/150
3: Instance 101/151
4: Instance 102/152

0

f851

Inverter operation at the

communications

loss action

(Network wire breaks)

0: Stop and Communication release
1: None
2: Deceleration stop
3: Coast stop
4: Emergency stop
5: Preset speed operation command
(Operating at the preset speed operation
frequency set with f852)

0

f852

Preset speed operation

selection

0: None
1 to 15:Preset speed

0

f853

Monitoring of

communication device

station address

Displays the MAC ID number assigned using the
DIP switch.
0 to 63

1

f854

Monitoring of

communications

device’s baud rate

Displays the network communication speed set
with the DIP switch.
0: 125kbps
1: 250kbps
2: 500kbps

0

f899

Network option

reset setting

0: None

1: Resetting the DEV002Z and the inverter

0

* When the parameters are changed, the power must be cycled (or set f899 to 1) to

the VF-AS1/PS1 for the changes to take effect.

Advertising