2. Exterior features

The external view of this option and the name of each part are shown below:

Danger

Prohibited

Do not change the switch setting when the power is on.
It could lead to electric shocks, or the option might breaks down or get
damaged.

2.1. DeviceNet connector

Used to connect DeviceNet network cables. The terminal is a plug-type and the signal of each

terminal is as follows.

Size of connectable wire: 0.3 to 1.5mm

2

(AWG 22 to 16), Strip-off length: 7mm

Tightening torque: 0.5 to 0.6 N·m
Recommended screwdriver: Small flat-blade screwdriver (blade thickness: 0.6mm, blade width:
3.5mm or less)

DeviceNet connector

(Refer to Section 2.1)

DeviceNet indicator

(Refer to Section 2.2)

Dip switch

(Refer to Section 4.3)

Panel mounting tabs

(Refer to Section 3)

Color

Symbol

Signal classification:

Red

V+

Network Power Supply (V+)

White

CAN_H

Communication signal (High)

Silver

SHIELD

Shield

Blue

CAN_L

Communication signal (Low)

Black

V-

Network Power Supply (V-)